Flow Control Valve

Pressure compensated. Check valve option for reverse-free flow. Four rotations of hand knob to facilitate the setting with ease. Thumb screw provision to retain valve setting. Stroke limiter available as an option.

DOWNLOAD BROUCHER
REQUEST A QUOTE
Max. working pr. 315 bar
Flow controlling capacity Min. 0.25 to 4, 8, 16 or 32 l/min.

Flow divider valve – FD

Flow divider valves provide dual flow from a single source at a predetermined ratio, regardless of load. Maximum dividing error is <5%, Threaded port body.

Inlet Flow 5 -10 10 -18 15 -30 30 -100
Flow controlling capacity Min. 0.25 to 4, 8, 16 or 32 l/min.
Dividing Ratio (%) 50 : 50

Throttle / Check Valve (Modular) – TCM 06

Double throttle cum check, non pressure compensated, modular construction. Can be used as Metering-in or Metering-out device.

Nominal flow and pressure ratings
Model Max. working pr. (bar) Max. flow l/min.
TCM 06 315 40

Throttle / Check Valve (Modular) – TCM 10

Double throttle cum check, non pressure compensated, modular construction. Can be used as Metering-in or Metering-out device.

Nominal flow and pressure ratings
Model Max. working pr. (bar) Max. flow l/min.
TCM 10 315 100

Throttle / Check Valve (Modular) – 2TCL10 — (New Product)

Double throttle cum check, 2TCL10 are meant for controlling flow in one direction in circuit by simple throttling of flow. Reverse flow is free and is independent of throttle condition in opposite direction in same path.